TM 5-4210-233-14&P-1
4-196. OUTRIGGER LIMIT SWITCHES - Continued
(3) Tag and disconnect wires from switch (9).
(4) Remove nut (10) from sleeve (11).
(5) Remove wiring harness (12) with nut (10), washer (13) and seal (14) from switch housing (15).
(6) Remove screws (1 6) and washers (1 7).
(7) Remove switch (9) from switch housing (15).
(8) Remove switch actuator (18) and seal (19).
b. Installation.
(1) Install switch actuator (18) and seal (19).
(2) Install switch (9) in switch housing (15) and secure with washers (17) and screws (16).
(3) Install wiring harness (12) with nut (10), washer (13) and seal (14). Thread nut (10) onto sleeve (1 1).
(4) Attach wiring harness (1 2) to switch (9).
(5) Install gasket (8), cover (7), lockwashers (6) and screws (5).
(6) Install switch housing (15) with screws (4), washers (3), lockwashers (2) and uts (1).
n
c.
Follow-on Maintenance.
(1) Retract outriggers (see para 2-14).
(2) Connect batteries (see para 4-114).