Click here to make tpub.com your Home Page

Page Title: Cleaning and Inspection
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 

TM 5-4210-233-14&P-1
4-19. WATER TANK LEVEL GAUGE - Continued
c.
Cleaning and Inspection.
(1) Clean lens (6).
(2) Inspect lens for cracks. If cracked, replace lens.
(3) Inspect wiring for fraying or cracked insulation.
If wiring is damaged, conta t Direct Support
c
Maintenance.
(4) Inspect bulb sockets, bulb contacts, and wiring for corrosion. Clean corrosion with emery cloth (Item
25, Appendix E). If corrosion cannot be cleaned, replace parts as required.
d.
Assembly.
(1) Install circuit board (12) in housing (13) with four screws (10) and spacers (11).
(2) Install plug (1) in housing (13) with four screws (14).
(3) Install bulbs (9) in circuit board (12).
(4) Install lens (6) and gasket (7) on plate (8). Secure in place with two screws (5).
e.
Installation.
(1) Position gauge in gauge panel.
(2) Secure gauge with clamp (4), washer (3) and locknut (2).
(3) Connect wiring harness to plug (1) on rear of gauge.
f.
Follow-on Maintenance.
(1) Install gauge panel (see para 4-18).
(2) Connect batteries (see para 4-114).
(3) Fill water tank and check operation of gauge with battery switch on.
4-174

Privacy Statement - Press Release - Copyright Information. - Contact Us

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business