TM 5-4210-233-14&P-1
Table 4-1. Unit PMCS-Continued
Item
Interval
No. W M
S
A
B
ITEM TO BE INSPECTED/Procedures
11
AERIAL LADDER/WATER TOWER ASSEMBLY - Continued
Ladder Assembly
*
Inspect carefully for signs of damage, cracks, broken welds. Inspect
extension mechanism for adequate lubrication.
Inspect hydraulic cylinders for leaks. Inspect cables and sheaves for
damage or improper operation. Report any deficiencies to Direct Support.
12
AUXILIARY POWER UNIT (APU)
Generator Brushes
*
Inspect for excessive wear. Replace as required.
APU Engine
*
Inspect primary and secondary fuel filter, oil filter, glow plug and crankcase
breather. Replace as required.