5-9. ALTERNATOR REPAIR. (Continued)
NOTE
Due to the application of Loctite to the brush housing screws during manufacturing it may be
necessary to apply heat to assist in the removal of these screws. Use a heat gun and hold on
each screw for approximately 45-60 seconds.
d. Remove four 8-32 screws (14) and remove regulator and brush housing assembly (13).
e. Remove three screws (15) and remove diode trio (16) from AC terminal board.
f. Remove three lock nuts (17) and through bolts (18).
CAUTION
Ensure that drive end housing (20) separates from stator (21) and that the stator remains
attached to the slip ring end housing (22) to avoid damage to the stator leads.
g. Remove rotor (19) and drive end housing assembly (20) from stator (21) and slip ring end housing assembly
(22).