TM5-4210-224-14&P
4-130. CONTROL SWITCHES AND GAUGES REPLACEMENT. (Continued)
REMOVAL
a.
Remove four screws securing water level
gauge and switch panel (3) to the instrument
panel (4).
b.
Remove indicator light circuit board by
removing two phillips screws from panel and
lift free of spacers.
c.
If required, desolder leads from circuit board.
NOTE
Prior to removing rocker switches (5, 6, 7
and 8) from water level gauge and switch
panel (3), tag wires to identify them at
installation.
d.
Remove leads from rocker switches (5, 6, 7,
and 8).
e.
Move rocker switch retainers and remove
rocker switches (5, 6, 7, and 8) from rear of
water level gauge and switch plate (3).
m.
Remove two screws securing oil pressure
gauge (13) to instrument panel cluster (11).
f.
Disconnect water tank level gauge wire plug.
n.
Remove oil pressure gauge (13).
g.
Remove two screws securing water tank level
gauge (9) to panel.
o.
Disconnect 1/4 inch plastic pipe at rear of
pump pressure gauge (14).
h.
Remove water tank level gauge (9).
p.
Remove two screws through pump pressure
i.
Remove screw securing fuel gauge (10) to
gauge bracket.
instrument panel cluster (11).
q.
Remove pump pressure gauge (14).
j.
Remove fuel gauge (10).
r.
Remove PTO knob (15)
by
turning
k.
Remove two screws securing water
counterclockwise by hand.
temperature gauge (12) to instrument panel
cluster (11).
s.
Loosen jam nut at rear of mounting bracket
(16).
l.
Remove water temperature gauge (12).
4-178
|