TM 5-4210-224-14&P
4-64. TANK PIPING REPLACEMENT. (Continued)
REMOVAL
a. Remove locking screw (1) and remove pipe
assembly (2).
b. Loosen clamp (3).
c. Slide clamp (3) off pipe support (4).
NOTE
Pipe is assembled as a single unit
and must be replaced entirely.
d. Remove pipe (5).
e. Remove phillips screw (6), washer (7), and hex
nut (8) securing pipe support (4) to baffle plate.
f. Remove pipe support.
INSTALLATION
a. Secure pipe support (5) to baffle plate with
phillips screw (6), washer (7), and hex nut (8).
b. Slide hose clamp (3) over pipe (5) and locate
hose clamp on pipe support (4).
c. Tighten hose clamp screw (6) to secure pipe (5).
e. Install water tank level sending unit (paragraph
d. Install pipe assembly (2) to outlet pipe with
locking screw (1).
f. Install hose bed floors (paragraph 4-59).
CAUTION
g. Install tank fill tower (paragraph 4-58).
When installing tank cover, ensure
h. Reconnect battery cables.
plastic pipe passes through smaller
hole inside fill tower.
4-100
|