4-63. WATER TANK LEVEL SENDER REPLACEMENT. (Continued)
INSTALLATION
a. Install gasket (8) and water tank level sending
unit (7) on water tank cover and secure with four
phillips screws (5) and hex nuts (6).
WARNING
When lifting an object make sure
the hoist and sling are fastened
securely. Be sure the item being
lifted does not exceed the capacity
of the lifting device.
b. Install tank cover (3) using a hoist.
e. Install hose bed floor (paragraph 4-59).
c. Secure tank cover (3) to tank (4) using 46
washers (2) and hex nuts (1).
f. Install fill tower bracket (paragraph 4-58).
d. Reconnect water tank sending unit to water
g. Reconnect battery cables.
level gauge connector.
4-64. TANK PIPING REPLACEMENT.
This task covers:
a. Removal
b. Installation
Equipment Condition
INITIAL SETUP:
Para. Condition Description
Tools
General Mechanics Tool Kit
Hoist
Removed
Materials/Parts
Tank Piping (120-90003)
General Safety Instructions
Engine OFF
Transmission in (N) neutral.
Parking brake and micro-brakelock set.
Batteries disconnected
Fire Pump and piping drained.
4-99
|