Table 2-5 Operator Preventive Maintenance Checks and Services - Continued
D - Daily
W - Weekly
A-
After
M-
Monthly
PROCEDURES
EQUIPMENT IS
INTERVAL
ITEM
ITEM TO BE
Check for and have repaired
NOT READY/
NO. D A W M
INSPECTED
or adjusted as necessary
AVAILABLE IF
12
Panels, Front
Visually inspect panels and step assemblies for
qq
Street Side,
structural damage.
and Step
Assemblies
13
Primer Tank
Visually inspect primer tank for leaks and structural
Oil level is
qq
damage. Check oil level in primer tank.
low.
Level should be approximately one inch below full
level. Replenish as necessary using SAE-30 oil.
HOSE BODY ASSEMBLY
14
Handrails and
Visually inspect handrails and mounting brackets
q
Mounting
for structural damage.
Brackets
15
qq
Lights
Perform operational checks on hose bed pick-up
Tail lights
lights, rear warning lights, tail lights and
are defective.
compartment lights. Inspect lights for defective
lamps, bulbs, or damaged lenses. Refer to next
higher level of maintenance for replacement or
repair.
16
qq
Doors
Check operation and general condition of compartment
doors.
17
Panels, Side,
Visually inspect panels and tread plates for
qq
Compartment
structural damage.
and Tread
Plates
18
qq
Rear
Visually inspect rear compartment and rear platform
Compartment
assembly for structural damage. Perform
and Platform
operational checks on rear back-up alarm and
Assembly
rear platform signal switch. Visually inspect
rear station charger for structural damage.
19 q
Hose Bed
Visually inspect hose bed fill tower bracket,
q
Assembly
floor, and supports for structural damage.
FIREFIGHTING SYSTEM
20
Priming Pump
Perform operational check on priming pump motor.
Priming pump
q
Visually inspect pump for corrosion or structural
not operating.
damage. Refer to next higher level of maintenance
Priming pump
if any defects are found.
damaged.
21
Fire Pump
Perform operational check on fire pump. Visually
Fire pump not
q
inspect pump for corrosion or structural damage.
operating.
Refer to next higher level of maintenance if any
Fire pump damaged.
defects are found.
22
Tank, Valves,
Visually inspect tank, valves, control rods and
Tank, valves,
qq
Control Rods,
piping for corrosion or structural damage. Refer
control rods
and Piping
to next higher level of maintenance if any defects
or piping
are found.
are damaged.
2-36