TM 5-4210-218-13&P
4-14. TEMPERATURE GAUGE REPLACEMENT. (Refer to Figure 4-6)
This task covers:
a.
Removal
b.
Installation
INITIAL SETUP
Equipment Condition
Tools
Reference
General Mechanics Tool Box, Item 1, Section
Cover removed from Recovery / Recharger
III, Appendix B.
paragraph 2-6.1
Materials/Parts
Air supply disconnected, paragraph 2-7
Temperature gauge
Appendix C
4-14.1. Removal.
a.
Remove two screws (1) securing temperature gauge to scale column.
b.
Retain four standoffs (2), plastic cover (3) and two screws (1) for reuse. Discard temperature gauge (4).
4-14. Installation.
a.
Place plastic cover (3) and two standoffs (2) on one screw (1).
b.
Hold new temperature gauge (4) in place and install top screw with standoffs and plastic cover but do not
tighten.
c.
Pass remaining screw (1) through plastic cover (3) and two standoffs.
d.
Holding temperature gauge (4) in place, install screw through temperature gauge mounting hole.
4-16
|