TRC 5 RA
integrations. The sample reading shall not exceed 2000
D-5. Report and reporting. In reference to the report
DPM. Notify the local Radiological Protection Officer for
and reporting required by paragraph 2-8 the following
operating procedures and information for this test. This
exceptions  apply  to  the  general  instructions  for
test is usually part of a special inspection.
preparation of the Munitions Surveillance Report (DA
(2) A test to determine brightness should be per- formed.
Form 984), Part II Results of Surveillance Test:
The lamp is required to illuminate the scales, reticules,
a.
Block 7.
Cite the serial number (where
etc. in the item, and they shall be readable under the
applicable) of each sample item subjected to inspection
conditions of Chart I, to an observer at a distance of 18
and/or test. Use Block 9a. If additional space is needed.
inches in a darkened room, after the observer has been
b. Block 8. Not applicable.
in total darkness for at least 15 minutes and after the
c. Block 9a. See above.
item has not been exposed to light for at least 24 hours
d. Block 9b. Type of light source(s) or isotope, i.e.,
prior to the test. The expected lamp life is determined by
tritium (H3), etc. These may be obtained from the items
Chart I.  Note the filters are Oreil Corporation Model
radioactive material label.
Numbers 5030 and 5095, or equivalent.
e. Block 10. The following shall be cited:
(1) Column a. Month and year of manufacture of
CHART I
light source(s). This may be obtained from the item's
radioactive material label.
OPTIONAL
EXPECTED
(2) Column b.  Date of conduct of inspection
CONDITION
LIFE TO
and/ or test per TRC-5RA.
RETEST
(3) Column c. Wipe test results, DPM.
.15 FILTER
4 YEARS
(4) Column d.  Notation of "x" in event light
.10 FILTER
3 YEARS
source lacks brightens or is physically damaged.
VISUAL
2 YEARS
(5) Column e. Notation of "x" in event the item
fails to function, or item radioactive material label is
missing.