Quantcast Setting Up and Adjusting the Cross-Leveling Fixture -820360412

 

Click here to make tpub.com your Home Page

Page Title: Setting Up and Adjusting the Cross-Leveling Fixture
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 

Share on Google+Share on FacebookShare on LinkedInShare on TwitterShare on DiggShare on Stumble Upon
Back
Setting Up and Adjusting the Cross-Leveling Fixture -820360411
Up
TM-9-1240-375-34-P Quadrant Fire Control: M17 (1290-01-037-3883) and M17A1 (1290-01-515-8260); Mount Telescope and Quadrant: M171 (1240-01-039-7273) Manual
Next
Setting Up and Adjusting the Cross-Leveling Fixture - continued -820360413
TM 9-1240-375-34&P
0073 00
TEST AND INSPECTION - Continued
Setting Up and Adjusting the Cross-Leveling Fixture - Continued
10
9
8
11
12
1 fc 4 1 4
7.
Install four lockwashers (9), four screws (10), four posts (11), and two plates (12) on adapter plate (8).
Tighten screws.
1
13
14
1 fc 4 1 5
8.
Place precision level (13) on block (14), perpendicular to axis of rotation.
9.
Level the cross-leveling fixture (1) in both cant and elevation.
NOTE
When installing test fixture adapter (2), ensure adapter keys (15) are parallel to top
of block within 0.1 mil.