Quantcast Setting Up and Adjusting the Cross-Leveling Fixture -820360411

 

Click here to make tpub.com your Home Page

Page Title: Setting Up and Adjusting the Cross-Leveling Fixture
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 

Share on Google+Share on FacebookShare on LinkedInShare on TwitterShare on DiggShare on Stumble Upon
Back
TEST AND INSPECTION -820360410
Up
TM-9-1240-375-34-P Quadrant Fire Control: M17 (1290-01-037-3883) and M17A1 (1290-01-515-8260); Mount Telescope and Quadrant: M171 (1240-01-039-7273) Manual
Next
Setting Up and Adjusting the Cross-Leveling Fixture -820360412
TM 9-1240-375-34&P
0073 00
4
5
1 1 /1 6 "
1 fc 4 1 1
3.
Tighten setscrew (4). Test fixture adapter face should be approximately 11/16 in. (1.75 cm) from block
(5).
NOTE
The mechanical adapter (P/N 10555619) illustrated below is for use with the M198
howitzer.
6
8
7
5
1 fc 4 1 2
4.
Assemble four screws (6), block (5), and two pins (7) on adapter plate (8).
1
8
1 fc 4 1 3
5.
Place adapter plate (8) on cant position of cross-leveling fixture (1).
6.
Lightly clamp adapter plate (8).
0073 00-3