NOTE
Before installing diopter adapter assembly, ensure that locating pins in eyepiece
extension are not damaged.
12.
Install new O-ring (14) (item 12A, WP 0146 00) in optical instrument extension (2).
13.
Place diopter adapter assembly (15) over locating pins in optical instrument extension (2).
14.
Apply sealing compound (item 13, WP 0152 00) to threads of eight machine screws (16).
15.
Install and tighten eight new lockwashers (17) (item 10, WP 0146 00) and eight machine screws (16)
and perform final inspection (WP 0106 00).