TM 9-1240-375-34&P
0103 00
ASSEMBLY
2
4
1
3
1 fc 7 2 9
1.
Position identification plate (1) on optical instrument extension (2).
WARNING
Use sealing compound in well-ventilated area away from open flame. Sealing
compound is harmful to skin and clothing and may give off harmful vapor. Exercise
care whenever sealing compound is used.
2.
Apply sealing compound (item 13, WP 0152 00) to threads of two machine screws (3).
3.
Install two new lockwashers (4) ( item 9, WP 0145 00) and two machine screws (3).
6
6
5
7
9
8
1 fc 7 3 1
1 fc 7 3 0
1 fc 7 3 2
4.
Place telescope mount stop (5) in slot on eyepiece cell assembly (6).
5.
Apply grease (item 15, WP 0152 00) in knob (7) and install on eyepiece cell assembly (6).
6.
Screw sleeve nut (8) on tight.
7.
Tighten setscrew (9) and apply sealing compound (item 13, WP 0152 00).
0103 00-7
|