TM 9-1240-375-34&P
0102 00
8
7
6
1 fc 6 9 6
6.
Remove four machine screws (6) and four lockwashers (7) from optical instrument latch set (8).
Discard lockwashers.
7.
Remove optical instrument latch set (8).
WARNING
If reticle cell assembly is not illuminated, do not perform any maintenance. Notify
Radiation Safety Officer (RSO). Perform wipe test. If wipe test passes, place M138
elbow telescope in plastic bag (item 5, WP 0152 00), seal with tape (item 20, WP
NOTE
Diopter adapter assembly may be disassembled while installed on M138 elbow
telescope.
12
9
13
10
11
1 fc 6 9 7
8.
Remove eight machine screws (9) and eight lockwashers (10). Discard lockwashers.
9.
Lift diopter adapter assembly (11) and O-ring (12) from optical instrument housing (13) being careful
not to damage locating pins in optical instrument housing. Remove and discard O-ring.
0102 00-3
|