TM 9-1240-375-34&P
0099 00
ASSEMBLY - Continued
19.
Position coupling (13) on shaft of rotating counter (14) and install headless straight pin (15). If
headless straight pin is loose, ream hole for next larger size headless straight pin and install.
20.
Position rotating counter (14) in counter box assembly (2).
NOTE
Be sure that headless straight pin (15) in coupling (13) is in slot of upper counter
shaft.
21.
Apply sealing compound (item 13, WP 0152 00) to threads of two machine screws (16).
22.
Install two new lockwashers (17) (item 4, WP 0142 00) and two machine screws (16).
23.
Position coupling (18) on shaft of rotating counter (19) and install headless straight pin (20). If
headless straight pin is loose, ream hole for next larger size headless straight pin and install.
24.
Position rotating counter (19) in counter box assembly (2).
25.
Apply sealing compound (item 13, WP 0152 00) to threads of two machine screws (21).
26.
Install two new lockwashers (22) (item 4, WP 0142 00) and two machine screws (21).
WARNING
Use adhesive in well-ventilated area away from open flame. Adhesive is harmful to
skin and clothing and may give off harmful vapor.
27.
Apply epoxy adhesive (item 4, WP 0152 00) carefully to two rotating counters (14 and 19), ensuring
that no epoxy gets onto number wheels of rotating counters.
28.
Place bracing plate (23) onto rotating counters (14 and 19), ensuring that no epoxy gets onto number
wheels of rotating counters.
29.
Place small weight on bracing plate (23) and allow to cure for 24 hours.
0099 00-6
|