TM 9-1240-375-34&P
0097 00
WARNING
Use sealing compound in well-ventilated area away from open flame. Sealing
compound is harmful to skin and clothing and may give off harmful vapor. Exercise
care whenever sealing compound is used.
3.
Inject sealing compound (item 13, WP 0152 00) into two drilled holes in optical element cell (2) to
secure optical instrument lens (4) and externally threaded ring (3).
4.
Apply a light coat of sealing compound (item 13, WP 0152 00) to safety relief valve (1) and install in
optical element cell (2).
WARNING
Use cleaning compound in well-ventilated area away from open flame. Cleaning
compound is harmful to skin and clothing and may give off harmful vapor.
5.
Clean optical instrument lens (4) with optical lens cleaning compound (item 11, WP 0152 00) and lens
paper (item 17, WP 0152 00).
END OF WORK PACKAGE
0097 00-3/4 blank
|