TM 9-1240-375-34&P
0096 00
DISASSEMBLY
WARNING
TRITIUM
GAS (H3)
When maintaining radioactively illuminated fire control equipment, follow radiation
hazard procedures in warning summary (M137 only).
1.
Remove four machine screws (1), four lockwashers (2), and elbow access cover (3). Discard
lockwashers.
2.
Remove O-ring (4) from elbow access cover (3). Discard O-ring.
3.
Remove four socket head capscrews (5) and four lockwashers (6). Discard lockwashers.
4.
Pull optical cell assembly (adapter) (7) from elbow telescope (8).
5.
Remove sealing compound from two setscrews (9) and remove setscrews from elbow telescope.
6.
Remove optical cell assembly (10) and O-ring (11) from elbow telescope (8). Discard O-ring.
1
2
3
8
11
10
4
5
6
7
9
1 fc 6 1 7
0096 00-2
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |