TM 9-1240-375-34&P
0095 00
DISASSEMBLY
WARNING
TRITIUM
GAS (H3)
When maintaining radioactively illuminated fire control equipment, follow radiation
hazard procedures in warning summary (M137 only).
1.
Remove two machine screws (1), two lockwashers (2), and gear assembly (3) from worm gear housing
body (4). Discard lockwashers.
2.
If damaged, remove two headless straight pins (5) from gear assembly (3).
3.
If damaged, remove two headless straight pins (6) from worm gear housing body (4).
3
6
4
2
1
5
1 fc 6 0 9
4.
Remove machine threaded plug (7), O-ring (8), compression helical spring (9), and detent plunger (10)
from worm gear housing body (4). Discard O-ring.
5.
Remove three machine screws (11), three lockwashers (12), plate (13), spring tension washer (14),
recessed washer (15), and O-ring (16) from worm gear housing body (4). Discard lockwashers, spring
tension washer, and O-ring.
6.
Remove wormshaft cap (17) from worm gear housing body (4). Remove O-ring (18) from wormshaft
cap. Discard O-ring.
0095 00-2
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |