Click here to make tpub.com your Home Page

Page Title: DISASSEMBLY
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 

TM 9-1240-375-34&P
0093 00
DISASSEMBLY
WARNING
TRITIUM
GAS (H3)
When maintaining radioactively illuminated fire control equipment, follow radiation
hazard procedures in warning summary (M137 only).
1.
Remove safety relief valve (1) from head housing (2).
2.
Remove two setscrews (3) and knob (4).
3.
Remove sealing compound and setscrew (5).
4.
Unscrew machine threaded bushing (6) and remove.
5.
Remove O-ring (7) from inside of machine threaded bushing (6) and discard.
6.
Remove external screw (8).
7.
Remove telescope actuator (9), plunger (10), and flat washer (11) from head housing (2).
8.
Unscrew plunger (10) from telescope actuator (9).
9.
Unscrew machine threaded plug (12).
10.
Remove compression helical spring (13), detent plunger (14), and O-ring (15). Discard O-ring.
11.
Remove four machine screws (16) and cover assembly (17) from head housing (2).
12.
Carefully remove nonmetallic round seal (18).
CAUTION
Glass can be damaged and scratched if handled carelessly and excessively.
13.
Remove sealing compound and remove optical instrument window (19).
14.
Remove sealing compound and unscrew prism pivot (20).
15.
Remove three machine screws (21) and plate cover (22).
NOTE
Check position of prism pivot before removing four setscrews.
16.
Remove sealing compound and four setscrews (23).
17.
Pull prism pivot (24) from head housing (2).
18.
Remove O-ring (25) from prism pivot (24). Discard O-ring.
0093 00-2

Privacy Statement - Press Release - Copyright Information. - Contact Us

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business