TM 9-1240-375-34&P
0088 00
DISASSEMBLY
WARNING
TRITIUM
GAS (H3)
When maintaining radioactively illuminated fire control equipment, follow radiation
hazard procedures in warning summary (M137 only).
5
7
9
4
1
3
6
2
8
1 fc 5 8 1
1.
Remove air valve cap (1), valve core (2), fluid valve stem (3), and retaining strap (4) from telescope
elbow (5).
2.
Remove setscrew (6).
3.
Depress detent plunger (7) and unscrew and remove plunger release lever (8).
4.
Carefully remove detent plunger (7) and compression helical spring (9) from telescope elbow (5).
CLEANING
Clean all parts per TM 9-254.
REPAIR OR REPLACEMENT
Repair is by replacement of authorized parts that do not meet inspection criteria. Refer to WP 0139 00.
0088 00-2
|