ASSEMBLY
WARNING
TRITIUM
GAS (H3)
When maintaining radioactively illuminated fire control equipment, follow radiation
hazard procedures in warning summary (M137 only).
2
1
4
2
3
3
1 fc 5 7 6
1 fc 5 7 5
1.
Apply a light coat of grease (item 16, WP 0152 00) to compression helical spring (1) and detent plate (2)
and install in cover plate (3).
WARNING
Use sealing compound in well-ventilated area away from open flame. Sealing
compound is harmful to skin and clothing and may give off harmful vapor. Exercise
care whenever sealing compound is used.
2.
Apply a light coat of sealing compound (item 14, WP 0152 00) to threads of post (4).
3.
Align threaded hole in detent plate (1) with slot in cover plate (3) and install post (4).