TM 9-1240-375-34&P
0083 00
SERVICE UPON RECEIPT OF MATERIEL - Continued
Checking Unpacked Equipment - Continued
10
7
12
8
6
9
10
11
1 fc 5 6 4
7.
Eyeshield (6) must not be torn or missing.
8.
Rotate azimuth knob assembly (7). It must turn smoothly and rotate the head assembly and azimuth
counter.
9.
Rotate azimuth knob assembly (7) in DIRECT mode. Counter should move 5 mils for each click.
10.
Rotate the correction knob assembly (8). It must turn smoothly and turn the correction counter.
11.
Check window (9) and lenses (10) for dirt or condensation.
WARNING
TRITIUM
GAS (H3)
When maintaining radioactively illuminated fire control equipment, follow radiation
hazard procedures in warning summary (M137 only).
12.
Check reticle (11) for dirt or condensation. Inspect reticle for illumination. Illumination must be
present and even.
13.
Inspect counter box windows (12) for illumination. Illumination must be present and even.
END OF WORK PACKAGE
0083 00-2
|