TM 9-1240-375-34&P
0080 00
INSTALLATION - Continued
6
10
9
8
1 fc 5 2 3
1 fc 5 2 4
9.
Apply sealing compound (item 13, WP 0152 00) to mating surfaces of access cover (8) and install on
quadrant support housing (6).
10.
Apply sealing compound (item 13, WP 0152 00) to threads of two socket head capscrews (9).
11.
Install two new lockwashers (10) (item 9, WP 0128 00) and two socket head capscrews (9).
13
11
12
13
14
15
16
8
17
1 fc 5 2 5
1 fc 5 2 6
12.
Apply sealing compound (item 13, WP 0152 00) to threads of two socket head capscrews (11) and two
socket head capscrews (12).
13.
Install four new lockwashers (13) (item 9, WP 0128 00), two socket head capscrews (11), and two socket
head capscrews (12), making sure the two longer socket head capscrews are installed in the center of
the access cover (8).