TM 9-1240-375-34&P
0079 00
WARNING
Use sealing compound in well-ventilated area away from open flame. Sealing
compound is harmful to skin and clothing and may give off harmful vapor. Exercise
care whenever sealing compound is used.
1.
Apply sealing compound (item 13, WP 0152 00) to mating surfaces of access cover (1) and install on
quadrant support housing (2).
2.
Apply sealing compound (item 13, WP 0152 00) to threads of two socket head capscrews (3).
3.
Install two new lockwashers (4) (item 9, WP 0128 00) and two socket head capscrews (3).
6
7
8
5
7
1
1 fc 5 1 1
4.
Apply sealing compound (item 13, WP 0152 00) to threads of two socket head capscrews (5) and two
socket head capscrews (6).
5.
Install four new lockwashers (7) (item 9, WP 0128 00), two socket head capscrews (5), and two socket
head capscrews (6), making sure the two longer socket head capscrews are installed in the center of the
access cover (1).
6.
Install two new lock wires (8) (item 21, WP 0152 00) by bending sharp ends into tops of four socket
head capscrews (5 and 6).
7.
Cover heads of four socket head capscrews (5 and 6) with sealing compound (item 13, WP 0152 00).
END OF WORK PACKAGE
0079 00-3/4 blank
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |