TEST AND INSPECTION - Continued
Cant Travel Inspection
1
2
1 fc 4 5 2
1.
Mount adapter plate (1) on optical instrument support (2).
3
4
1 fc 4 5 3
2.
Center bubble in cross level vial (3) and bubble in elevation level vial (4).
5
1
1 fc 4 5 4
3.
Set fire control quadrant (5) to 178 mils and place on adapter plate (1).