TM 9-1240-375-34&P
0073 00
WARNING
Use sealing compound in well-ventilated area away from open flame. Sealing
compound is harmful to skin and clothing and may give off harmful vapor. Exercise
care whenever sealing compound is used.
16.
Place a dab of sealing compound (item 13, WP 0152 00) on slotted end of eccentric (22) and to threads of
externally threaded ring (21).
17.
Reinstall eccentric (22) and externally threaded ring (21) and turn eccentric until bubble in elevation
level vial (15) centers.
18.
Tighten externally threaded ring (21).
19.
Ensure bubble in elevation level vial (15) is centered.
20
1 fc 4 4 3
20.
Apply sealing compound (item 13, WP 0152 00) to setscrew (20). Tighten setscrew.
15
1 fc 4 4 4
21.
Apply sealing compound (item 13, WP 0152 00) to outside of externally threaded ring (21) and to end of
elevation level vial (15).
0073 00-17
|