0072 00
REPAIR OR REPLACEMENT
NOTE
Replace adapter if bent or otherwise damaged causing M17 quadrant to mount
incorrectly.
Repair is by replacement of authorized parts that do not meet inspection criteria. Refer to WP 0124 00 and
ASSEMBLY
1
4
2
3
1 fc 4 0 8 b
WARNING
Use sealing compound in well-ventilated area away from open flame. Sealing
compound is harmful to skin and clothing and may give off harmful vapor. Exercise
care whenever sealing compound is used.
1.
Apply sealing compound (item 13, WP 0152 00) to two socket capscrews (1).
2.
Position two machine keys (2) on adapter (3) and secure using two new lockwashers (4) (item 3,
WP 0125 00) and two socket capscrews (1).
0072 00-3