TM 9-1240-375-34&P
0067 00
CLEANING
WARNING
Use cleaning compound in well-ventilated area away from open flame. Cleaning
compound is harmful to skin and clothing and may give off harmful vapor.
Clean all parts with cleaning compound (item 12, WP 0152 00).
REPAIR OR REPLACEMENT
Repair is by replacement of authorized parts that do not meet inspection criteria. Refer to WP 0122 00.
ASSEMBLY
4
4
2
2
1
1
3
3
O L D C O N F IG U R A T IO N
NEW
C O N F IG U R A T IO N
1 fc 3 4 0
NOTE
The old configuration bearing parts can be cleaned and repacked but, if replacement
is necessary, bearing parts will be replaced with new configuration items.
1.
Apply light coat of grease (item 15, WP 0152 00) to bearing seat (1) and plain bearing (2). Install
bearing seat and plain bearing in optical instrument rocker (3).
2.
Apply light coat of grease (item 15, WP 0152 00) to bearing seat (4).
3.
Install bearing seat (4) and tighten. Torque to 16 to 18 in.-lb (1.80 to 2.03 N-m) for M171 mount or 150
in.-lb (17.06 N-m) for M171A1 mount using torque adapter.