0065 00
ASSEMBLY
NOTE
Apply light coat of grease (item 15, WP 0152 00) to all machined surfaces.
Apply light coat of grease (item 16, WP 0152 00) to all O-rings.
4
2
5
1
6
M 171A1
3
7
7
1 fc 3 1 3
CAUTION
To prevent equipment damage of M171A1 mount, ensure that elevation level vial
and cross level vial are positioned correctly. Visually check for special slot in
elevation level vial.
1.
Install two level covers (1), elevation level vial (2), cross level vial (3), two eccentrics (4), and two
externally threaded rings (5) in bearing housing assembly (6).
WARNING
Use sealing compound in well-ventilated area away from open flame. Sealing
compound is harmful to skin and clothing and may give off harmful vapor. Exercise
care whenever sealing compound is used.
2.
Apply sealing compound (item 13, WP 0152 00) to threads of two setscrews (7). Wipe off excess sealing
compound with a clean wiping rag (item 18, WP 0152 00) and tighten setscrews.
3.
Cover two setscrews (7) with sealing compound (item 13, WP 0152 00).