TM 9-1240-375-34&P
0060 00
DISASSEMBLY
WARNING
TRITIUM
GAS (H3)
When maintaining radioactively illuminated fire control equipment, follow radiation
hazard procedures in warning summary.
3
4
2
1
7
8
6
5
1 fc 2 7 8
1.
Remove two socket capscrews (1) and two lockwashers (2). Discard lockwashers.
2.
Pry two machine keys (3) out of grooves in optical instrument support (4).
3.
Remove four socket capscrews (5), four lockwashers (6), two thumbscrews (7), and two thumbscrew
assemblies (8). Discard lockwashers.
REPAIR OR REPLACEMENT
Repair is by replacement of authorized parts that do not meet inspection criteria. Refer to WP 0121 00.