Click here to make tpub.com your Home Page

Page Title: Backlash Inspection - continued
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 

TM 9-1240-375-34&P
0057 00
1
5
6
1 fc 2 4 8
3.
Scribe index line (5) on M17/M18 or M17A1/M18A1 quadrant (1) near elevation knob (6).
7
1 fc 2 4 9
NOTE
An index pointer may be made from 1/16 in. diameter rod with a sharp point on one
end. The index pointer may be held in place using a small C-clamp (7).
11
12
9
10
5
8
6
1 fc 2 5 0
4.
Place index pointer (8) on the elevation knob (6) directly opposite the scribed index line (5). The index
pointer may have to be moved for each elevation setting.
5.
Place fire control quadrant (9) on top of mounting bracket (10) and level bubble in fire control quadrant
level (11) using micrometer knob (12) and record reading.
0057 00-9

Privacy Statement - Press Release - Copyright Information. - Contact Us

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business