TM 9-1240-375-34&P
0057 00
TEST AND INSPECTION - Continued
Mounting M17/M18 or M17A1/M18A1 Quadrant on Optical Equipment Test Fixture
2
3
4
1
1 fc 2 4 2
1.
Position M17/M18 or M17A1/M18A1 quadrant (1) on adapter (2) of optical equipment test fixture (3).
2.
Install and tighten four machine bolts (4).
8
5
6
3
7
1 fc 2 4 3
3.
Place plate-mounted level (5) parallel to block (6) of optical equipment test fixture (3).
4.
Rotate cant handwheel (7) until bubble (8) in plate-mounted level (5) centers.
0057 00-6
|