TM 9-1240-375-34&P
0052 00
4
5
3
2
1
1 fc 1 7 4
M17/M18 Quadrant
1.
Remove two machine screws (1), two lockwashers (2), and window plate (3) from quadrant cover (4).
Discard lockwashers.
2.
Remove sealing compound from edge of optical instrument window (5) and remove window.
4
9
8
7
6
1 fc 1 7 5
M17/M18 Quadrant
3.
Remove two machine screws (6), two lockwashers (7), and window plate (8) from quadrant cover (4).
Discard lockwashers.
4.
Remove sealing compound from edge of optical instrument window (9) and remove window.
REPAIR OR REPLACEMENT
1.
Replace entire cover assembly if cracked, broken, or damaged in any way that would allow foreign
matter to enter interior of the M17/M18 quadrant.
2.
Repair by replacing authorized parts that do not meet inspection criteria. Refer to WP 0111 00 and
0052 00-3
|