TM 9-1240-375-34&P
0051 00
REPAIR OR REPLACEMENT
1.
Replace fire control level assembly if any threads are stripped or vial holder is damaged.
2.
Fire control level may be replaced if it is cracked but still illuminated. Dispose of broken fire control
level in accordance with RSO instructions. If fire control level is cracked and not illuminated, notify
RSO. Perform wipe test under RSO supervision. Remove, bag, and secure assembly under RSO
direction and await wipe test results. If contaminated, dispose of assembly per RSO instructions. If
assembly is not contaminated, replace fire control level. Dispose of replaced fire control level per RSO
instructions.
3.
Repair is by replacement of authorized parts that do not meet inspection criteria. Refer to WP 0111 00
and WP 0113 00.
ASSEMBLY
2
3
4
5
6
1
1 fc 1 6 1
M17/M18 Quadrant
1.
If removed, install new headless straight pin (1).
2.
Place level cover (2) in vial holder (3).
3.
Slide fire control level (4) into vial holder (3) and secure with eccentric (5) and externally threaded ring
(6).
0051 00-4
|