TM 9-1240-375-34&P
0048 00
ADJUSTMENT - Continued
NOTE
If bubble in elevation level cannot be adjusted within one graduation, more
adjustment is required. Perform steps 6 through 11. Otherwise, perform step 5.
5.
Install new lock wire (7) (item 21, WP 0152 00).
6
8
9
1 fc 0 9 4
M17 Quadrant
6.
Remove externally threaded ring (8) and eccentric (9).
7.
Place a dab of sealing compound (item 13, WP 0152 00) on slotted end of eccentric (9) and to threads of
externally threaded ring (8).
8.
Reinstall eccentric (9) and externally threaded ring (8) and turn eccentric until bubble in elevation
level (6) centers.
9.
Tighten externally threaded ring (8).
10.
Apply sealing compound (item 13, WP 0152 00) to outside of externally threaded ring (8).
11.
Install new lock wire (item 21, WP 0152 00).
END OF WORK PACKAGE