BEARING HOUSING ASSEMBLY - Continued
Table 1. Troubleshooting Procedures.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
1
2
4
5
3
1 fc 0 3 5
Check for incorrect adjustment
Adjust bubble in cross level vial
1. BUBBLE IN CROSS LEVEL
(1) or bubble in elevation level
VIAL (1) OR BUBBLE IN
vial (2) correctly (WP 0073 00).
ELEVATION LEVEL VIAL (2)
DOES NOT CENTER WITHIN
ONE GRADUATION LINE.
2. CROSS LEVEL VIAL (1) OR
1. Check cross level vial (1) or
1. Contact RSO immediately.
ELEVATION LEVEL VIAL (2)
elevation level vial (2) for
2. Perform wipe test under RSO
HAS UNEVEN OR NO
supervision.
3. Remove, bag, and secure
device under RSO direction
and await wipe test results.
4. If contaminated, dispose of
device per RSO instructions.
5. If device is not contaminated,
replace cross level vial (1) or
elevation level vial (2)
6. Dispose of replaced vial per
RSO instructions.
0019 00-2
|