TM 9-1240-375-34&P
0016 00
Table 1. Troubleshooting Procedures - Continued.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
5. If device is not contaminated,
evacuate to next higher level
of maintenance.
Observe visually in darkened
1. Contact RSO immediately.
3. CROSS LEVEL VIAL (2) OR
area.
ELEVATION LEVEL VIAL (3)
2. Perform wipe test under RSO
IS CRACKED OR BUBBLE IS
supervision.
ELONGATED BUT STILL
3. Remove, bag, and secure
ILLUMINATED.
device under RSO direction
and await wipe test results.
4. Howitzer should be secured
until wipe test results show
howitzer is not contaminated.
5. If contaminated, dispose of
device per RSO instructions.
6. If device is not contaminated,
evacuate to next higher level
of maintenance.
Observe visually in darkened
1. Contact RSO immediately.
4. CROSS LEVEL VIAL (2) OR
area.
ELEVATION LEVEL VIAL (3)
2. Perform wipe test under RSO
IS CRACKED OR BUBBLE IS
supervision.
ELONGATED AND NOT
3. Remove, bag, and secure
ILLUMINATED.
device under RSO direction
and await wipe test results.
4. If contaminated, dispose of
device per RSO instructions.
5. If device is not contaminated,
evacuate to next higher level
of maintenance.
END OF WORK PACKAGE
0016 00-3/4 blank
|