TM 9-1240-375-34&P
0013 00
WORM SHAFT ASSEMBLY
Table 1. Troubleshooting Procedures.
NOTE
The following steps are written and illustrated for the M17/M18 quadrant but also
apply to the M17A1/M18A1 quadrant.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
1
1
1 fc 0 3 1
M17/M17A1 Quadrant
M18/M18A1 Quadrant
WARNING
TRITIUM
GAS (H3)
When maintaining radioactively illuminated fire control equipment, follow radiation
hazard procedures in warning summary.
1. ELEVATION KNOB (1)
1. Check for incorrectly adjusted
Adjust retainers (WP 0055 00).
EXCEEDS 0.7-MIL
retainers.
BACKLASH.
2. Check for worn or damaged
Replace worm shaft assembly
parts.
and replace parts as required
and authorized (WP 0055 00).
END OF WORK PACKAGE
0013 00-2