Table 1. Direct Support Troubleshooting Procedures - Continued.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
3. Replace batteries (item 8, WP
a. Unscrew battery caps.
b. Remove batteries using
magnet in battery cap.
c. Install new batteries in
same direction as diagram
on battery enclosure.
d. Replace battery caps.
4. Replace battery enclosure
assembly (4) (WP 0047 00).
5. Notify next higher level of
maintenance.
2. ELEVATION LEVEL VIAL (1)
Observe visually.
Notify next higher level of
AND CROSS LEVEL VIAL (2)
maintenance.
HAVE NO BUBBLE, BUT
ARE STILL ILLUMINATED.
Observe visually.
1. Perform the cannon tube
3. BUBBLE IN ELEVATION
synchronization procedure
LEVEL VIAL (1) IS NOT
(TM 9-1025-211-34/TM 9-
SYNCHRONIZED WITH
1025-215-25&P).
M198/M777 HOWITZER
TUBE.
2. If unable to complete
synchronization procedure,
notify next higher level of
maintenance.
Observe visually.
4. ELEVATION LEVEL VIAL (1)
AND CROSS LEVEL VIAL (2)
WARNING
CANNOT BE READ
Use cleaning compound in
CLEARLY IN MIRROR.
well-ventilated area away
from open flame. Cleaning
compound is harmful to
skin and clothing and may
give off harmful vapor.
Clean mirror with optical lens
cleaning compound (item 11, WP
END OF WORK PACKAGE