TM 55-1925-292-14&P
0026 00
INSTALLATION
1. Position meter module MM-35 (figure 5, item 3) in the enclosure and secure it with the four screws
(figure 5, item 2).
2. Connect the electrical wiring to P1 (figure 5, item 1) using the labels from step 2 of Removal as a guide.
Remove the labels.
3. Perform the Follow-On Service procedure at the end of this work package.
BATTERY CHARGER/TRANSFER MODULE BC-35 REPLACEMENT
REMOVAL
1. OPEN the enclosure following the Open Enclosure procedure of this work package.
2. Label and disconnect the electrical wiring from P1 (figure 6, item 1), P2 (figure 6, item 2), and TB1 (figure 6,
item 3).
3. Remove the four screws (figure 6, item 4) that secure battery charger/transfer module BC-35 (figure 6, item 5),
and remove it from the enclosure.
CP-35
PS 35
MM-35
BE-35
BC-35
4
1
5
BATTERY
TROUBLE
2
3
4
Figure 6. Battery Charger/Transfer Module BC-35 Replacement
0026 00-7
|