TM 55-1925-292-14&P
0005 00
AQUEOUS FILM FORMING FOAM (AFFF) SYSTEM ACTIVATION
NOTE
The AFFF system must only be operated in conjunction with the diesel engine-driven
fire pump.
1. Perform the Fire Monitor Operation procedure in this work package.
2. OPEN valve FM-84 (figure 17, item 1), AFFF TK SUCT. This valve is located below the deckplate.
Engine Room
AMS 1
FM-13
FM-1
(BELOW
EOS)
ASW-17
ASW-20
ASW-19
PUMP DRIVE
ENGINE
FO-31
HYDRAULIC
CA-6
SUPPLY TANK
ASW-22
FM-84
1
Figure 17. AFFF Tank Suction Valve Location
3. Start the AFFF pump by completing the following actions:
a. At the main switchboard in the EOS, set the AFFF PUMP circuit breaker (figure 18, item 1) to ON.
b. At the AFFF pump motor controller (figure 19) complete the following actions:
(1)
Set the ON-OFF switch (figure 19, item 1) to ON.
0005 00-18
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |