TM55-1905-243-24&P
REVISION
APPROVED
DESCRIPTION
DATE
ZONE
REV
1
8
TUNNEL VENT COVER
9
SEE NOTES 10 AND 11
25-C
SEE VIEW
WTRTT BHD 17/WTRTT BHD 25
(TUNNEL SIDE)
25
18
COVER HINGE
28-B
SEE VIEW
2 PLACES
1
A
8
HINGE BRACKET
22
26-A
SEE VIEW
2 PLACES
(12'')
EXISTING TUNNEL VENT OPENING
2''
31-A
SEE VIEW
17
SEE NOTE 21
FOR HOLD DOWN ASSEMBLY
DETAIL AND INSTALLATION
(CLOSED POSITION)
19
37-A
VIEW 28-C
SEE VIEW
1''
MAIN DECK
1
MAIN DECK
FM-200 SYSTEM MISCELLANEOUS MODS
2
INSTALLATION OF TUNNEL VENT COVERS
TUNNEL
VIEW 30-C
20
HOLD DOWN LUG
BELOW MAIN DECK
1
VIEW 31-C
FM-200 SYSTEM MISCELLANEOUS MODS
37-C
1 PLACE AS SHOWN (WTRTT BHD 25, PORT SIDE)
SEE VIEW
8
INSTALLATION OF DOOR SEALS
FM-200 SYSTEM MISCELLANEOUS MODS
1 PLACE SIMILAR (WTRTT BHD 17)
ENGINE ROOM DOOR
INSTALLATION OF DOOR SEALS
SCALE 1 1/2''=1'-0''
VIEW 25-C
MAIN DECK
ENGINE ROOM DOOR
SEE NOTE 16
(1'')
LONG BHD 5'-0'' OFF C
TUNNEL VENT COVER
L
MAIN DECK
FOR HOLD BACK ASSEMBLY DETAIL AND INSTALLATION
LOOKING OUTBOARD
SCALE 1 1/2"=1'-0"
LONG BHD 5'-0'' OFF C
34-A
L
(OPEN POSITION) SEE VIEW
1''
SCALE 3/4''=1'-0''
LOOKING INBOARD
2
SCALE 3/4''=1'-0''
5 1/16
16
1''
2
(4'')
5''
2X
16
1''
2
STEEL DOOR
5''
DOOR JAMB
15
16
1''
2
1''
(1 )
2
SEE NOTE 17
STEEL DOOR
22
REF
28
A
VIEW 28-B
18
8
REF
REF
18
REF
COVER HINGE
30
REF
22
REF
9
DOOR JAMB
MAIN DECK
VIEW 25-A
A
VIEW 26-A
INSTALLATION OF HINGE PIN
8
ONE SIDE SHOWN
SEE NOTES 8 AND 9
HINGE BRACKET
MIN CLEARANCE
MAIN DECK
OTHER SIDE OPPOSITE
LONG BHD
AS REQD (TYP)
5'-0'' OFF C
L
CONTRACT NUMBER
UNLESS OTHERWISE SPECIFIED
U.S. ARMY TANK AUTOMOTIVE COMMAND
DIMENSIONS ARE IN INCHES
DTRSXX-XX-X-XXXXX
VIEW 30-A
VIEW 31-A
WARREN, MICHIGAN 48397-5000
TOLERANCES ON:
CONTRACTOR
BOTTOM SEAL
FM-200 SYSTEM MISCELLANEOUS MODS
2 PLACES
3 PLACES
ANGLES
STEEL DOOR
U.S. ARMY LCU-2000
XXX
INSTALLATION OF DOOR SEALS
DRAWN BY
DATE
RPE (FP) CLASS APPROVAL
ENGINE ROOM DOOR
FM-200 SYSTEM
BO
05/15/98
PHILIP DINENNO
MAIN DECK
CHECKER
ENGINEER
VIEW 28-A
STATE OF TENNESSEE
MISCELLANEOUS MODS
LONG BHD 5'-0'' OFF C
JAS
MB
L
LIC. NO. 015882
SIDE SEAL
LOOKING INBOARD
CLASS DESIGN APPROVAL
AS BUILT DRAWING
SIZE
CAGE CODE
M. CAPUTO 8/1/03
MARK GENTILE
SCALE 1''=1'-0''
LCU-2000-5553-2
D
19207
CLASS DRAWING APPROVAL
AS BUILT CHECKED
M. GENTILE 8/8/03
SHEET
4 OF 6
SCALE
MARK GENTILE 4/28/99
FO-32
FP-63/(FP-64 blank)
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |