PUMP OPERATOR'S PANEL WIRE HARNESS REPLACEMENT - Continued
PUMP OPERATOR'S PANEL WIRE HARNESS REPLACEMENT - Continued

Maintenance Manual For Tactical Fire Fighting Truck (Tfft) Model M1142 - 3 Page Navigation
  740    741    742    743    744  745  746    747    748    749    750  
img
DRAFT
TM 5-4210-249-13&P-3
0459
INSTALLATION
NOTE
Route pump operator's panel wire harness as noted prior to removal.
Install cable ties, split looms, and cushion clips as noted.
1.
Install pump operator's panel wire harness (205) into vehicle.
2.
Connect pump operator's panel wire harness connector DO 2 (203) to main wire harness DO 2
connector (204).
3.
Connect pump operator's panel wire harness connector DO 1 (201) to main wire harness DO 1
connector (202).
4.
Connect pump power distribution connector DP 2 (199) to pump house distribution box DP 2 connector (200).
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
TFFT03314
5.
Install wire 3895 (197) to pump house ground bolt (198) with lockwasher (196) and nut (195).
0459-21