• Home
  • Download PDF
  • Order CD-ROM
  • Order in Print
TERMINAL BLOCK (PASS-THROUGH) REPLACEMENT
TERMINAL BLOCK (PASS-THROUGH) REPLACEMENT - Continued

Maintenance Manual For Tactical Fire Fighting Truck (Tfft) Model M1142 - 3 Page Navigation
  447    448    449    450    451  452  453    454    455    456    457  
img
DRAFT
TM 5-4210-249-13&P-3
0429
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
TFFT02561
4.
Remove nut (11), lockwasher (12), and wire 1640 (13) from ground terminal block (6). Discard lockwasher.
5.
Remove nut (14), lockwasher (15), and five wires 1138 (16) from positive terminal block (10). Discard
lockwasher.
6.
Remove two nuts (17), screws (18), and ground terminal block (6) from pump house power distribution
box (19).
7.
Remove two nuts (20), screws (21), and positive terminal block (10) from pump house power distribution
box (19).
END OF TASK
INSTALLATION
CAUTION
Do not overtighten nuts when installing terminal blocks. Failure to comply may
cause damage to equipment.
1.
Install positive terminal block (10) on pump house power distribution box (19) with two screws (21) and
nuts (20).
2.
Install ground terminal block (6) on pump house power distribution box (19) with two screws (18) and
nuts (17).
3.
Install five wires 1138 (16) on positive terminal block (10) with lockwasher (15) and nut (14).
4.
Install wire 1640 (13) on ground terminal block (6) with lockwasher (12) and nut (11).
0429-2


Privacy Statement
Press Release
Contact

© Copyright Integrated Publishing, Inc.. All Rights Reserved.