EXTENDABLE FLOODLIGHT REPLACEMENT - Continued
EXTENDABLE FLOODLIGHT REPLACEMENT - Continued

Maintenance Manual For Tactical Fire Fighting Truck (Tfft) Model M1142 - 3 Page Navigation
  203    204    205    206    207  208  209    210    211    212    213  
img
DRAFT
TM 5-4210-249-13&P-3
0354
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
TFFT00838
6.
Remove four screws (12) and washers (13) from pump housing (14) and extendable floodlight (15).
NOTE
Perform Step (7) if bracket needs to be removed.
7.
Remove four nuts (16), eight washers (17), four lockwashers (18), screws (19), and bracket (11) from pump
housing (14). Discard lockwashers.
END OF TASK
INSTALLATION
NOTE
Perform Step (1) if bracket was removed.
Both extendable floodlights are installed the same way.
Install cable ties as required.
1.
Install bracket (11) on pump housing (14) with four screws (19), lockwashers (18), eight washers (17), and
four nuts (16).
2.
Position extendable floodlight (15) on pump housing (14) and bracket (11)
3.
Install extendable floodlight (15) on pump housing (14) with four washers (13) and screws (12).
4.
Tighten two setscrews (10) on bracket (11).
5.
Install plug (5) on three wires (7), (8), and (9) and tighten three screws (6).