DRAFT
TM 5-4210-249-13&P-2
0211
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
TFFT00355
3.
Connect two connectors (12) on fans (13).
CAUTION
Install preformed packing on hose fittings to prevent refrigerant from leaking.
4.
Install preformed packing (11) and hose (10) on condenser assembly (9).
5.
Install preformed packing (8) and hose (7) on condenser assembly (9).
6.
Install hose (5) and hose clamp (4) on elbow (6) by tightening screw (3).
7.
Attach hose (5) to vehicle with three loop clamps (2) and screws (1).
END OF TASK
FOLLOW-ON MAINTENANCE
Service/recharge crew cab air conditioner (WP 0217)
END OF TASK
END OF WORK PACKAGE
0211-5/(6 blank)