DRAFT
TM 5-4210-249-13&P-2
0182
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
TFFT04599
Step 32.
Disconnect main wire harness pump house wire harness connector. With a test lead
set, check for continuity across wire 2852 (red) from main wire harness pump house
wire harness connector, terminal 2 to pump house wire harness pump house heater
diagnostic module connector, terminal A.
a.
If there is continuity, repair wire 2852 in main wire harness if repairable
(TM 9-2320-325-14&P), or replace main wire harness (WP 0455).
b.
If there is no continuity, repair wire 2852 in pump house wire harness if
repairable (TM 9-2320-325-14&P), or replace pump house wire
harness (WP 0458).
END OF TASK
FOLLOW-ON MAINTENANCE
Remove wheel chocks (TM 9-2320-347-10)
END OF TASK
END OF WORK PACKAGE
0182-25/(26 blank)