PIPING HEAT TRACE DOES NOT OPERATE PROPERLY - Continued
PUMP HOUSE HEATER DOES NOT OPERATE PROPERLY

Maintenance Manual For Tactical Fire Fighting Truck (Tfft) Model M1142 - 2 Page Navigation
  693    694    695    696    697  698  699    700    701    702    703  
img
DRAFT
TM 5-4210-249-13&P-2
0181
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
WARNING
ICON 3, 2, 13
120 Volts AC is present during heat trace operation. Use extreme caution when
operating heat trace with trace junction and thermostat boxes open. Failure to
comply may result in electrical shock or injury to personnel.
Heat trace may become extremely hot during normal operations. Use caution when
checking operation of heat trace. Failure to comply may result in serious burns.
Step 15.
Check if passenger side tank to pump heat trace cable is heating.
If passenger side tank to pump heat trace cable is not heating, go to
Step 17.
Step 16.
Check if A/B foam heat trace cable is heating.
a.
If A/B foam heat trace cable is not heating, go to Step 17.
Step 17.
Turn hydraulic generator OFF (WP 0021). Turn engine OFF (TM 9-2320-347-10).
Open and check associated splice connectors for loose or damaged connections.
a.
If connections are tight and free from damage, replace non-operating
heat trace cable (WP 0606).
b.
If connections are loose or damaged, tighten connections or replace
splice connector (WP 0606).
END OF TASK
FOLLOW-ON MAINTENANCE
Remove wheel chocks (TM 9-2320-347-10)
END OF TASK
END OF WORK PACKAGE