DRAFT
TM 5-4210-249-13&P-2
0166
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
TFFT03869
NOTE
24-volt battery charger specifications suggests that charger will attempt to charge
batteries unless battery voltage drops below 10 VDC in a 24 VDC system.
Step 11.
Reconnect batteries (TM 9-2320-325-14&P). Check for at least 10 VDC across 24 VDC
series connected batteries from 24 VDC main positive terminal to 24 VDC main
negative terminal.
a.
If at least 10 VDC are present, replace 24-volt battery
charger (WP 0359).
b.
If there are less than 10 VDC, replace batteries (WP 0368).
0166-10